Pump reference
FMC M0608 triplex plunger pump
FMC / M06Documented source recordPage / reference 12–13
Supply identity and fitment need confirmation; this reference is not a price or stock commitment.
- Source brand
- FMC
- Model family
- M06
- Source reference
- M0608
What the source says
TechnipFMC’s supplied reciprocating-pump catalog identifies M0608 as an M06 horizontal triplex plunger configuration with a 1.000 in plunger and a 1.5 in stroke. The model row lists 7.3 GPM at 475 rpm and 9.2 GPM at 600 rpm; the M06 section rates continuous speed at 475 rpm and intermittent speed at 600 rpm. Confirm the fluid end, packing, inlet conditions and required duty before selection; catalog flow values are not a supplied-pump guarantee.
Prepare an inquiry
Identification reference. Supply identity and fitment require confirmation. No price or stock commitment.
About this reference
FMC M0608 triplex plunger pump — reference M0608. This entry is organized under FMC / M06 using the supplied documentation. The source reference identifies a catalog entry; it does not establish interchangeability or current availability. This pump entry supports equipment identification and configuration enquiries. Selection requires a documented operating point and a confirmed supply scope, including whether the drive and accessories are included. The M0608–M0615 standard connection row lists 1.5 in suction and 1.0 in discharge, while the separate HV row lists 2.0 in suction and 1.5 in discharge. The M06 material table distinguishes forged fluid cylinders from cast ductile-iron cylinders; these alternatives are not a single universal M0608 specification. The NPSHr chart is explicitly for disc valves with one spring of standard stiffness, and the page instructs adding 5 ft for stiff springs. Confirm the valve and fluid-end configuration before using the chart or ordering connections.
Selection & verification
For M0608, verify the 1.000 in plunger and distinguish the 475 rpm continuous catalogue point (7.3 GPM) from the 600 rpm intermittent point (9.2 GPM). Page 13 lists 1.5 in suction / 1.0 in discharge for standard M0608–M0615, and 2.0 / 1.5 in for the separate HV option. Confirm the installed fluid cylinder and port sizes; do not assume HV is supplied.
Have the equipment reference ready?
Search this model in the catalog ↗Documented details
| Configuration (catalog) | Horizontal triplex plunger / 卧式三柱塞 |
|---|---|
| Plunger diameter, model row | 1.000 in |
| Stroke, M06 family | 1.5 in |
| Displacement, model row | 0.0153 US gal/rev |
| Continuous / intermittent speed ratings | 475 / 600 rpm |
| Catalog capacity at 475 / 500 / 600 rpm | 7.3 / 7.7 / 9.2 GPM |
| Standard suction / discharge, non-HV row | 1.5 / 1.0 in |
| HV suction / discharge, separate catalog option | 2.0 / 1.5 in; not assumed supplied / 不默认随货配置 |
Before you inquire
Confirm the pump nameplate, exact model, existing part number and configuration. Reference numbers are not company stock codes.
Source documentation
TechnipFMC Reciprocating pumps — M06 specifications and performance data (supplied archive copy)
Page / reference: 12–13
A third-party source-page image (PDF page 1) is withheld from this public index while redistribution rights are checked. The cited model and page reference remain available for technical review. Contact Dongli ↗
Questions before ordering
How do I identify reference M0608?
Compare M0608 and the listed name “FMC M0608 triplex plunger pump” with the original part marking and the M06 documentation. Include the full number and suffix in your inquiry.
Does an M0608 include the HV connection sizes by default?
The catalogue does not establish that. It separates standard M0608–M0615 connections (1.5 in suction, 1.0 in discharge) from the M0608–M0615 HV row (2.0 in suction, 1.5 in discharge). Identify the actual fluid cylinder and ports before ordering or planning an installation.
Can M0608 be selected by model name alone?
No. The FMC / M06 grouping is a source-catalog context. Confirm the full reference, equipment revision and drawing details before treating this item as a match. Material, pressure rating, stock and interchangeability require separate confirmation.
FMC / M0608
Ready to discuss this reference?
Save this source reference, then include the nameplate, configuration and required quantity for Dongli to verify.
Dongli