All pump models / source boundaries

Check pumps by flow and pressure

Enter a duty point and review the evidence state of each catalogue model. Numerical screening begins only after the original source, exact configuration and same-duty data are verified.

Catalogue records do not prove stock or fitment. No catalogue model yet has a verified chain from model to original source, fluid end/configuration and paired flow-pressure point, so this page does not issue model matches.

406pump catalogue records
32category pending
0numerically screenable
34non-pump records separate

Record required duty

Use US GPM or m³/h.

Use psi or MPa; confirm whether this is discharge gauge or differential pressure.

Duty-point result

Enter the duty point to see how many models can be screened.

The remaining pump records need source verification; they cannot be called a match or unsuitable.

NOV manufacturer table scenarios (6 model families)

This compares values from the same liner column in six NOV Performance Charts: its maximum discharge-pressure figure and listed GPM at a printed speed are each at least the input. Only printed rows at or below marked rated speed are used. No interpolation or catalogue-unit selection is made.

Before reading the figures: the booklet labels discharge pressure in psi but does not establish the pressure datum or suction condition. Source values do not establish fitment to a field unit.

Enter discharge gauge pressure and required flow to review source-table figures.

Open the NOV original performance charts (PDF pp. 28–30) ↗

The same booklet has a separate 12-P-160 High Pressure chart on PDF p. 31. That configuration is not compared here and must not be mixed with the standard p. 30 table. Open the original page ↗

Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.

Family resource rows (listed by model; images/manuals are not cross-inherited)

Link-health badges come from an ingested audit snapshot at build time; pages do not live-HEAD external hosts. “Verified 200” is the snapshot-day result, not proof the URL still works now—re-audit the snapshot after URL changes.

For each liner, only the lowest printed speed whose GPM is at least the input is shown. A larger printed flow does not prove the field unit can deliver the exact target. The NOV heading says discharge pressure in psi without independently establishing its pressure datum or suction condition. Flow assumes 100% volumetric efficiency; the booklet says it is general information, not for design. Installed fluid end, liner, drive and application still require engineering review.

Failing FM-45 original scan (5 cylinder sizes)

The printed p. 2 table gives maximum pressure and a 50–100 crankshaft RPM displacement range (rods deducted) on the same cylinder-size row. This only finds rows whose printed displacement interval contains the flow input and whose listed pressure maximum is not below the pressure input. No interpolation or assignment to either FM-45 catalogue unit is made.

The displacement range is neither measured delivered flow nor a full performance curve; a precise speed cannot be inferred from an in-range number. The table does not independently define the pressure datum, suction conditions or revision date. A numerical comparison does not establish unit suitability.

Enter discharge gauge pressure and required flow to review the FM-45 source table.

Open the Failing original (PDF p. 1 / printed p. 2) ↗

Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.

Family resource rows (listed by model; images/manuals are not cross-inherited)

The original says displacement is calculated with rods deducted, and states 900 lb working pressure and 1,800 lb test pressure on the FM-45 summary line. Only the printed cylinder-size rows are compared here; test pressure is not a working rating. Delivered flow, corresponding speed, and installed cylinder size, drive and applicable revision still require separate evidence for both catalogue records.

American Mfg AME0413HD source-table scenario (withheld)

The values of this scenario table come from American Mfg OEM documents locked in pump ledger-1899 and are withheld before public release; this entry remains source_needed and is not a selection basis.

AME0413HD OEM documents are locked in the pump ledger; no link is offered. This entry remains source_needed.

Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.

Myers Aplex SC-230 source-table scenario

Pentair Myers datasheet MA3013 (10-15-21) prints the SC-230 English capacity table (plunger size, maximum pressure, and GPM at 250–450 RPM). IOM AP-03-105 PDF p. 6 prints the same model envelope: 310 hp at 450 RPM, 18,320 lb rod load, 4.5 in stroke, and 2,208 psi maximum continuous working pressure. This lists only the lowest printed speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.

The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. IOM prints plunger sizes 3-1/4″–4″ while the datasheet also lists sizes outside that range—both prints are retained with no silent trim. Weights: datasheet SC-230 2,680 lb vs IOM forged-steel liquid end about 2,900 lb; both retained. The SC-230H table is not inherited. The aplex-sc-230 card remains a table-lead clue only.

Enter discharge gauge pressure and required flow to review the SC-230 printed points.

Open MA3013 datasheet (PDF p. 1) ↗

Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.

Capacity rows come from the MA3013 SC-230 table; envelope fields checked against the IOM. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit SC-230H.

Myers Aplex SC-35 source-table scenario

Pentair Myers datasheet MA3016 (10-15-21) prints the SC-35 English capacity table (piston size, maximum pressure, and GPM at 200–625 RPM). IOM AP-03-102 has no SC-35 engineering section; this scenario uses the datasheet alone. This lists only the lowest printed speed on each piston row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.

The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. Engineering-data max working pressure prints 2,700 psi while the English table max cell is 2,716 psi—both retained with no silent correction. No SC-35H / base variant is inherited. The aplex-sc-35 card remains a table-lead clue only.

Enter discharge gauge pressure and required flow to review the SC-35 printed points.

Open MA3016 datasheet (PDF p. 1) ↗

Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.

Capacity rows come from the MA3016 SC-35 table. Results list printed points only and do not prove field delivery or bind an installed configuration.

Myers Aplex SC-45L source-table scenario

Pentair Myers datasheet MA3004 prints the SC-45L English capacity table (plunger size, maximum pressure, and GPM at 200–600 RPM). IOM AP-03-102 PDF p. 11 prints the same model envelope: 60 hp at 600 RPM, 5,280 lb rod load, 2.25 in stroke, 1,683 psi maximum continuous working pressure, 2,500 psi hydrostatic test, and plunger range 2″–2-1/4″. This lists only the lowest printed speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.

The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. Weights: datasheet SC-45L 463 lb vs IOM ductile-iron liquid end about 440 lb; both retained. The SC-45 and SC-45H tables are not inherited. The aplex-sc-45l card remains a table-lead clue only.

Enter discharge gauge pressure and required flow to review the SC-45L printed points.

Open MA3004 datasheet (PDF p. 1 SC-45L table) ↗

Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.

Capacity rows come from the MA3004 SC-45L table; envelope fields checked against the IOM. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit SC-45 / SC-45H.

Myers Aplex SC-65 source-table scenario

Pentair Myers datasheet MA3007 (07-15-21) prints the SC-65 English capacity table (plunger size, maximum pressure, and GPM at 200–550 RPM). IOM AP-03-102 PDF p. 15 prints the same model envelope: 92 hp at 550 RPM, 7,216 lb rod load, 2.75 in stroke, 3,000 psi maximum continuous working pressure, and 4,500 psi hydrostatic test. This lists only the lowest printed speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.

The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. IOM prints plunger sizes 2-3/4″–2-1/4″ while the datasheet SC-65 table also lists smaller sizes—both prints are retained with no silent trim. Datasheet weight header lists L/H only (base SC-65 omitted); IOM lists aluminum-bronze / ductile-iron / forged-steel approximates—retained. The SC-65L and SC-65H tables are not inherited. The aplex-pump-sc-65 card remains a table-lead clue only.

Enter discharge gauge pressure and required flow to review the SC-65 printed points.

Open MA3007 datasheet (PDF p. 1 SC-65 table) ↗

Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.

Capacity rows come from the MA3007 SC-65 table; envelope fields checked against the IOM. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit SC-65L / SC-65H.

Myers Aplex SC-65L source-table scenario

Pentair Myers datasheet MA3007 prints the SC-65L English capacity table (plunger size, maximum pressure, and GPM at 200–550 RPM). IOM AP-03-102 PDF p. 14 prints the same model envelope: 92 hp at 550 RPM, 7,216 lb rod load, 2.75 in stroke, 1,815 psi maximum continuous working pressure, 2,725 psi hydrostatic test, and plunger range 2-3/4″–2-1/4″. This lists only the lowest printed speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.

The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. IOM prints plunger sizes 2-3/4″–2-1/4″ while the datasheet SC-65L table also lists 3.000″ (Piston)—both prints are retained with no silent trim. Weights: datasheet SC-65L 750 lb vs IOM aluminum-bronze / ductile-iron / forged-steel about 750 / 730 / 775 lb; retained. The SC-65 and SC-65H tables are not inherited. The aplex-sc-65l card remains a table-lead clue only.

Enter discharge gauge pressure and required flow to review the SC-65L printed points.

Open MA3007 datasheet (PDF p. 1 SC-65L table) ↗

Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.

Capacity rows come from the MA3007 SC-65L table; envelope fields checked against the IOM. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit SC-65 / SC-65H.

Myers Aplex SC-115L source-table scenario

Pentair Myers datasheet MA3011 prints the SC-115L English capacity table (plunger size, maximum pressure, and listed GPM). Engineering data: 1,815 psi maximum continuous working pressure and 2,700 psi hydrostatic test. No dedicated IOM section. This lists only the lowest capacity-consistent speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.

The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. Title says QUINTUPLEX while the header prints NO. OF PLUNGERS 3—both retained, not silent-corrected. Column headers print 350–550 RPM, but GPM ÷ gal/rev equals 200/250/350/450/550—comparison uses capacity-consistent speeds and holds the header conflict. SC-115 / SC-115H tables are not inherited; no base/H catalogue slugs to invent. The aplex-sc-115l card remains a table-lead clue only.

Enter discharge gauge pressure and required flow to review the SC-115L printed points.

Open MA3011 datasheet (PDF p. 1 SC-115L table) ↗

Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.

Capacity rows come from the MA3011 SC-115L table. Results list printed flow points; speeds follow capacity-consistent columns while the header conflict remains held. They do not prove field delivery, bind an installed configuration, or inherit SC-115 / H.

Myers Aplex SC-300L source-table scenario

Pentair Myers datasheet MA3015 (10-15-21) prints the SC-300L English capacity table (plunger size, maximum pressure, and GPM at 200–400 RPM). Engineering data: 1,626 psi maximum continuous working pressure and 2,500 psi hydrostatic test; L maximum speed 400 RPM, rod load 16,780 lb, weight 4,800 lb (separate from SC-300(H)). No dedicated IOM section. This lists only the lowest printed speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.

The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. SC-300 / SC-300H tables are not inherited; no base/H catalogue slugs to invent. The aplex-sc-300l card remains a table-lead clue only.

Enter discharge gauge pressure and required flow to review the SC-300L printed points.

Open MA3015 datasheet (PDF p. 1 SC-300L table) ↗

Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.

Capacity rows come from the MA3015 SC-300L table. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit SC-300 / SC-300H.

Kerr KZ-3150PT source-table scenario

The Kerr Pumps OEM PDF (kerrpumps.com/public/pdf/KZ-3150PT.pdf) prints the KZ-3150PT capacity table: diameter, maximum pressure, and GPM at 100–575 RPM. Envelope: 16.7 BHP, 1.5 in stroke, continuous 525 RPM, API-674 recommended maximum 475 RPM, minimum 200 RPM, frame load 1,842 lb. This lists only the lowest printed speed on each diameter row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.

Page-1 Specifications Configuration prints Horizontal Triplex Piston while the capacity page title prints Triplex Plunger Pump—both retained, not silent-corrected. Duty is Continuous Duty; the table also prints 100 RPM below the minimum and 575 RPM above continuous, labeled when hit. Displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. Sibling KZ-3150 (non-PT) has no catalogue slug and is not inherited. The kerr-kz-3150pt card remains a table-lead clue only.

Enter discharge gauge pressure and required flow to review the KZ-3150PT printed points.

Open Kerr KZ-3150PT OEM PDF (capacity page) ↗

Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.

Capacity rows come from the Kerr OEM KZ-3150PT.pdf. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit slug-less KZ-3150.

02 / SOURCE REVIEW

Source-conflict holds (6 catalogue records)

All six coverage source-conflict records: both printed sides are retained, never silent-corrected, and no numerical shortlist window is opened. Cards below cite page-level coordinates, SHA and source URLs; installed configuration and applicable revision remain unbound.

numericalWindowAllowed=false · Source conflict · no numerical window

SC-170L / SC-170DD: max continuous working pressure

In-site Dupagro-marked manuals print 2020 psi on PDF p.4; Pentair MA3012 (10-15-21) prints 1862 psi (SC-170L) and 1136 psi (SC-170DD) for the same field. Both prints are retained with no silent choice. No numerical window until the applicable revision and installed configuration are bound.

Open catalogue card(SC-170L)Open catalogue card(SC-170DD)

Next steps

What we need from you

Nameplate / serial, fluid end, and applicable document revision to bind an installed SC-170L or SC-170DD configuration.

Already on hand locally

In-site legacy booklet vs Pentair MA3012 printed pressure sides with page/SHA; hold copy and catalogue links.

Must not do

No numerical window; do not silently pick a side; do not treat either print as a catalogue installed-unit match.

Hold reasons:applicable_revision_unbound · installed_configuration_unbound · printed_source_discrepancy · intermittent_duty_and_efficiency_basis_on_ma3012

AW1122BCD: 750 RPM capacity print conflict + ball-valve 635 RPM limit

Parts book PDF p.1 prints 44.2 GPM / 167 LPM at 750 RPM; service manual PDF p.11 prints 442 GPM while the same page still lists 167 LPM. Both prints are held. PDF p.10 lists AW1122BCD as Ball with a 635 RPM ball-valve maximum—so even the coherent 44.2@750 point exceeds that limit. No numerical window.

Open catalogue card(AW1122BCD)

  • Printed side A 44.2 US GPM / 167 LPM PDF page 1 SHA256 be704111300e0b31… Open this side ↗
  • Printed side B 442 US GPM PDF page 11 · Page 11 of 64 SHA256 041730f9a8f6e4c9… Open this side ↗
  • Additional printed limit AW1122BCD listed Ball; ball-valve maximum 635 RPM PDF page 10 · Page 10 of 64 Open this side ↗

Next steps

What we need from you

Nameplate / valve type (disc vs ball) and installed speed duty; confirm applicable parts-book and service-manual revisions.

Already on hand locally

OEM product page plus parts-book and service-manual prints (750 RPM conflict and 635 RPM ball limit) with SHA/pages.

Must not do

No numerical window; do not crown 442 or 44.2 as the sole truth; do not inherit as capacity for other American MFG models.

Hold reasons:printed_source_discrepancy_442_vs_44_2 · ball_valve_speed_limit_635_rpm · installed_configuration_unbound · pressure_basis_and_suction_pending · document_reproduction_terms

AW1118D: Displacement print conflict

Parts book PDF p.1 prints AW1118 Displacement 0.0394 gal / 0.149 L; service manual PDF p.11 prints 0.0589 gal / 0.223 L (same figures as AW1122 on that page). GPM/LPM columns and 1000 psi agree; only Displacement conflicts. Identity on PDF p.10 lists Disc AW1118D. Both prints held; no numerical window.

Open catalogue card(AW1118D)

  • Printed side A AW1118 Displacement 0.0394 gal / 0.149 L PDF page 1 SHA256 be704111300e0b31… Open this side ↗
  • Printed side B AW1118 Displacement 0.0589 gal / 0.223 L (same figures as AW1122 on that page) PDF page 11 · Page 11 of 64 SHA256 041730f9a8f6e4c9… Open this side ↗

Next steps

What we need from you

Nameplate proving Disc AW1118D; installed configuration and applicable original revisions; a live dedicated product URL if one exists.

Already on hand locally

Parts-book vs service-manual Displacement prints and identity-page coordinates; productPage already null (404).

Must not do

No numerical window; do not treat the Displacement conflict as resolved; do not substitute the AW1122BCD product page for this model.

Hold reasons:printed_source_discrepancy_displacement · installed_configuration_unbound · pressure_basis_and_suction_pending · document_reproduction_terms · dedicated_product_page_404_family_pdfs_used

AW1118B: Displacement conflict + ball-valve 635 RPM

Same AW1118 Displacement print conflict as AW1118D (0.0394 vs 0.0589 gal). Identity lists Ball AW1118B with a 635 RPM ball-valve maximum. Capacity table has no B/D split. Both prints held; no numerical window.

Open catalogue card(AW1118B)

  • Printed side A AW1118 Displacement 0.0394 gal / 0.149 L; Ball Valve Max Speed Rating 635 RPM PDF page 1 SHA256 be704111300e0b31… Open this side ↗
  • Printed side B AW1118 Displacement 0.0589 gal / 0.223 L PDF page 11 · Page 11 of 64 SHA256 041730f9a8f6e4c9… Open this side ↗
  • Additional printed limit 635 RPM ball-valve maximum applies to AW1118B

Next steps

What we need from you

Nameplate proving Ball AW1118B; ball-valve duty and installed configuration; applicable originals or a live dedicated product URL.

Already on hand locally

Same Displacement print conflict as AW1118D, 635 RPM ball limit, and identity page; productPage already null (404).

Must not do

No numerical window; do not inherit AW1122 numeric conclusions beyond this hold; do not substitute search or other-model pages.

Hold reasons:printed_source_discrepancy_displacement · ball_valve_speed_limit_635_rpm · installed_configuration_unbound · pressure_basis_and_suction_pending · document_reproduction_terms · dedicated_product_page_404_family_pdfs_used

SC-45: MA3004 vs IOM working-pressure / hydrostatic conflict

MA3004 engineering max WP prints 3000 psi (English table ≈2988 psi at 1.500 in) with hydrostatic 4500 psi; IOM AP-03-102 PDF p.12 prints 3500 psi continuous WP and 5250 psi hydrostatic. Both prints held with no silent correction. SC-45L / SC-45H are not inherited. No numerical window.

Open catalogue card(SC-45)

  • Printed side A Engineering max WP 3000 psi (table max at 1.500 in ≈ 2988 psi); hydrostatic 4500 psi PDF page 1 · MA3004 (07-15-21) SHA256 c9fd81a04cc7cd56… Open this side ↗
  • Printed side B Max continuous WP 3500 psi; hydrostatic 5250 psi PDF page 12 · AP-03-102 SHA256 17900052de74eb9f… Open this side ↗

Next steps

What we need from you

Nameplate confirming base SC-45 (not L/H); applicable datasheet and IOM revisions plus installed configuration.

Already on hand locally

MA3004 vs AP-03-102 IOM working-pressure / hydro-test prints with page/SHA.

Must not do

No numerical window; do not inherit SC-45L/SC-45H tables or manuals; do not silently merge sides.

Hold reasons:printed_source_discrepancy_wp_and_hydro · installed_configuration_unbound · applicable_revision_unbound · does_not_inherit_sc45l_or_sc45h

Secondary-summary holds (3 catalogue records)

All coverage secondary-summary records: catalogue specs are baojia.pump_brands digests only, not original same-configuration duty points. Cards below cite existing research. No numerical window. Not OEM equipment or installed-unit proof. Reseller-hosted copies are not silently promoted.

numericalWindowAllowed=false · Secondary summary · no numerical window · not OEM equipment proof

FMC 420: secondary summary only

Catalogue specs flow 28 GPM (6.4 m³/h) / pressure 48 bar (700 psi) come from baojia.pump_brands secondary digest fields, not an original same-configuration duty point. The R05-found reseller-hosted FMC Bean CD Series brochure is not promoted to a verified manufacturer-hosted applicable original. No numerical window. Not OEM equipment or installed-unit proof.

Primary action: open catalogue card

Open catalogue card(FMC 420)

When inquiring or verifying, attach a nameplate or serial; do not treat the reseller PDF as a verified OEM applicable original.

Source field
baojia.pump_brands
Catalogue specs (secondary digest fields — not a selection window)
28 GPM (6.4 m3/h) · 48 bar (700 psi)Directory specs fields only — secondary digest, not a same-duty OEM binding
Still missing for selection
original_manufacturer_source · installed_configuration · same_duty_data
Research cite
recovery/quality-plan/PUMP-SELECTION-ALL-MODELS-20261103/source-research-r05.json#fmc_420_435

Next steps

What we need from you

Manufacturer-hosted applicable original (capacity/configuration) plus nameplate / installed configuration — not reseller digests alone.

Already on hand locally

Catalogue baojia.pump_brands secondary specs, this hold copy, and a reviewable reseller-hosted FMC Bean brochure link (not OEM promotion).

Must not do

No numerical window; do not promote the reseller brochure to a manufacturer-hosted applicable original; not OEM equipment or installed-unit proof.

Hold reasons:secondary_summary_only_baojia_pump_brands · no_verified_manufacturer_hosted_applicable_original · numerical_window_forbidden · not_oem_equipment_or_installed_unit_proof

FMC 435: secondary summary only

Catalogue specs flow 50 GPM (11.4 m³/h) / pressure 69 bar (1000 psi) come from baojia.pump_brands secondary digest fields, not an original same-configuration duty point. Same hold as FMC 420: the reseller-hosted brochure is not silently promoted. No numerical window. Not OEM equipment or installed-unit proof.

Primary action: open catalogue card

Open catalogue card(FMC 435)

When inquiring or verifying, attach a nameplate or serial; do not treat the reseller PDF as a verified OEM applicable original.

Source field
baojia.pump_brands
Catalogue specs (secondary digest fields — not a selection window)
50 GPM (11.4 m3/h) · 69 bar (1000 psi)Directory specs fields only — secondary digest, not a same-duty OEM binding
Still missing for selection
original_manufacturer_source · installed_configuration · same_duty_data
Research cite
recovery/quality-plan/PUMP-SELECTION-ALL-MODELS-20261103/source-research-r05.json#fmc_420_435

Next steps

What we need from you

Manufacturer-hosted applicable original plus nameplate / installed configuration; do not substitute the reseller CD Series digest.

Already on hand locally

Catalogue secondary specs, hold copy, and the same reseller-hosted brochure link as FMC 420 (kept non-promoted).

Must not do

No numerical window; do not silently promote the reseller brochure; not OEM equipment or installed-unit proof.

Hold reasons:secondary_summary_only_baojia_pump_brands · no_verified_manufacturer_hosted_applicable_original · numerical_window_forbidden · not_oem_equipment_or_installed_unit_proof

MFG 435: secondary summary only (not AW1122BCD)

Catalogue specs flow 201 L/min (53 GPM) / pressure 69 bar (1000 psi) come from baojia.pump_brands. Numerical resemblance to an AW1122 Parts Book cell does not establish relation to AW1122BCD; no inherited AW11 performance. No numerical window. Not OEM equipment or installed-unit proof.

Primary action: open catalogue card

Open catalogue card(MFG 435)

When inquiring or verifying, attach a nameplate or serial; do not treat the reseller PDF as a verified OEM applicable original.

Source field
baojia.pump_brands
Catalogue specs (secondary digest fields — not a selection window)
201 L/min (53 GPM) · 69 bar (1000 psi)Directory specs fields only — secondary digest; numerical resemblance to AW1122 cells is not identity
Still missing for selection
original_manufacturer_source · installed_configuration · same_duty_data
Relation to AW1122BCD
not established by a manufacturer original; no inherited AW11 performance
Research cite
recovery/quality-plan/PUMP-SELECTION-ALL-MODELS-20261103/source-research-r28.json#american_mfg_mfg_435

Next steps

What we need from you

MFG 435-specific manufacturer original and nameplate; if claiming a link to AW1122BCD, provide OEM identity proof (no numeric look-alike equality).

Already on hand locally

Catalogue secondary specs, hold copy, and the research note that relation to AW1122BCD is not established.

Must not do

No numerical window; do not inherit AW11 performance; do not treat numeric resemblance as the same model.

Hold reasons:secondary_summary_only_baojia_pump_brands · relation_to_aw1122bcd_not_established · no_inherited_aw11_performance · numerical_window_forbidden · not_oem_equipment_or_installed_unit_proof

SC-170L / DD max continuous working pressure compare (hold explanation only — not a numerical window)

Catalogue modelOlder library copy (Dupagro) · PDF p. 4Pentair MA3012 (marked 10-15-21) · PDF p. 4Status
SC-170L 2,020 psi60130A999 · 2006-06-16Open older source page ↗ 1,862 psiMA3012 (10-15-21)Open Pentair source page ↗ Source conflict · no numerical window
SC-170DD 2,020 psi60187A999 · 2003-04-24Open older source page ↗ 1,136 psiMA3012 (10-15-21)Open Pentair source page ↗ Source conflict · no numerical window

A conflict hold is not a selection result. Do not pick a side, interpolate, or treat either print as an installed-unit match. Bind nameplate, serial, liquid end and applicable document before engineering review. Protected PDFs are not mirrored.

03 / CATALOGUE

Review every model status

Browse all pump-category and unclassified records by model, brand or category. Original catalogue links remain available.

Evidence tiers: catalogue records with manufacturer family table leads 17 · source conflicts 6 · secondary summaries only 3 · original table or configuration pending 380.

FMC 420, FMC 435 and MFG 435 are the three secondary-summary holds (cards above): baojia.pump_brands digests only. No numerical window; not OEM equipment proof.

Showing 438 records

Mud pumps272
HDD pumps108
Well service pumps23
Mining pumps2
Water well pumps1
Category pending32

Unclassified records cannot yet be assigned to a pump category. Valves and quick-change systems are excluded from pump screening.

04 / ORIGINAL SOURCES

Original-source family index (deduped navigation)

Jump by family to the scenario blocks above. Primary capacity deep links stay only in those scenario blocks. Resource bars provide catalogue cards and in-site manuals. Extra OEM pages below are for review only — not model recommendations and not an expanded catalogue index.

Expand for family anchors and extra OEM pages (IOM / service / conflict-side originals).

NOV Type P
Failing FM-45
American Mfg AME0413HD
Myers Aplex SC-230
Myers Aplex SC-35
Myers Aplex SC-45L
Myers Aplex SC-65
Myers Aplex SC-65L
Myers Aplex SC-115L
Myers Aplex SC-300L
Kerr KZ-3150PT
Source-conflict / SC-170
MP-16 reference

05 / REVIEW

Final selection still needs

  • Required flow, pressure definition, fluid, temperature and continuous or intermittent duty.
  • Installed nameplate, serial number, fluid end, liner or plunger, drive power and suction conditions.
  • A configuration-specific manufacturer curve or table and engineering sign-off for the site.