Duty-point result
Enter the duty point to see how many models can be screened.
The remaining pump records need source verification; they cannot be called a match or unsuitable.
NOV manufacturer table scenarios (6 model families)
This compares values from the same liner column in six NOV Performance Charts: its maximum discharge-pressure figure and listed GPM at a printed speed are each at least the input. Only printed rows at or below marked rated speed are used. No interpolation or catalogue-unit selection is made.
Before reading the figures: the booklet labels discharge pressure in psi but does not establish the pressure datum or suction condition. Source values do not establish fitment to a field unit.
Enter discharge gauge pressure and required flow to review source-table figures.
Open the NOV original performance charts (PDF pp. 28–30) ↗
The same booklet has a separate 12-P-160 High Pressure chart on PDF p. 31. That configuration is not compared here and must not be mixed with the standard p. 30 table. Open the original page ↗
Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.
Family resource rows (listed by model; images/manuals are not cross-inherited)
Link-health badges come from an ingested audit snapshot at build time; pages do not live-HEAD external hosts. “Verified 200” is the snapshot-day result, not proof the URL still works now—re-audit the snapshot after URL changes.
For each liner, only the lowest printed speed whose GPM is at least the input is shown. A larger printed flow does not prove the field unit can deliver the exact target. The NOV heading says discharge pressure in psi without independently establishing its pressure datum or suction condition. Flow assumes 100% volumetric efficiency; the booklet says it is general information, not for design. Installed fluid end, liner, drive and application still require engineering review.
Failing FM-45 original scan (5 cylinder sizes)
The printed p. 2 table gives maximum pressure and a 50–100 crankshaft RPM displacement range (rods deducted) on the same cylinder-size row. This only finds rows whose printed displacement interval contains the flow input and whose listed pressure maximum is not below the pressure input. No interpolation or assignment to either FM-45 catalogue unit is made.
The displacement range is neither measured delivered flow nor a full performance curve; a precise speed cannot be inferred from an in-range number. The table does not independently define the pressure datum, suction conditions or revision date. A numerical comparison does not establish unit suitability.
Enter discharge gauge pressure and required flow to review the FM-45 source table.
Open the Failing original (PDF p. 1 / printed p. 2) ↗
Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.
Family resource rows (listed by model; images/manuals are not cross-inherited)
The original says displacement is calculated with rods deducted, and states 900 lb working pressure and 1,800 lb test pressure on the FM-45 summary line. Only the printed cylinder-size rows are compared here; test pressure is not a working rating. Delivered flow, corresponding speed, and installed cylinder size, drive and applicable revision still require separate evidence for both catalogue records.
American Mfg AME0413HD source-table scenario (withheld)
The values of this scenario table come from American Mfg OEM documents locked in pump ledger-1899 and are withheld before public release; this entry remains source_needed and is not a selection basis.
AME0413HD OEM documents are locked in the pump ledger; no link is offered. This entry remains source_needed.
Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.
- No external OEM PDF No dedicated in-site manual No in-site image
- Open catalogue card (existing image)(AME0413HD)
- No dedicated parts-book title in the in-site library(No dedicated AME0413HD title in manualLibrary; do not inherit american-mfg-4_5x5-ff-axfm-parts-book (different product; filename merely contains american-mfg).)
- No catalogue overlay image mapped for this card(No catalogue overlay mapped for american-mfg-ame0413hd; do not AI-generate a product photo.)
- OEM PDFs link to the manufacturer site; not mirrored into the repo. manualLibrary.runtimeImportAllowed=false.
Myers Aplex SC-230 source-table scenario
Pentair Myers datasheet MA3013 (10-15-21) prints the SC-230 English capacity table (plunger size, maximum pressure, and GPM at 250–450 RPM). IOM AP-03-105 PDF p. 6 prints the same model envelope: 310 hp at 450 RPM, 18,320 lb rod load, 4.5 in stroke, and 2,208 psi maximum continuous working pressure. This lists only the lowest printed speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.
The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. IOM prints plunger sizes 3-1/4″–4″ while the datasheet also lists sizes outside that range—both prints are retained with no silent trim. Weights: datasheet SC-230 2,680 lb vs IOM forged-steel liquid end about 2,900 lb; both retained. The SC-230H table is not inherited. The aplex-sc-230 card remains a table-lead clue only.
Enter discharge gauge pressure and required flow to review the SC-230 printed points.
Open MA3013 datasheet (PDF p. 1) ↗
Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.
Capacity rows come from the MA3013 SC-230 table; envelope fields checked against the IOM. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit SC-230H.
Myers Aplex SC-35 source-table scenario
Pentair Myers datasheet MA3016 (10-15-21) prints the SC-35 English capacity table (piston size, maximum pressure, and GPM at 200–625 RPM). IOM AP-03-102 has no SC-35 engineering section; this scenario uses the datasheet alone. This lists only the lowest printed speed on each piston row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.
The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. Engineering-data max working pressure prints 2,700 psi while the English table max cell is 2,716 psi—both retained with no silent correction. No SC-35H / base variant is inherited. The aplex-sc-35 card remains a table-lead clue only.
Enter discharge gauge pressure and required flow to review the SC-35 printed points.
Open MA3016 datasheet (PDF p. 1) ↗
Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.
Capacity rows come from the MA3016 SC-35 table. Results list printed points only and do not prove field delivery or bind an installed configuration.
Myers Aplex SC-45L source-table scenario
Pentair Myers datasheet MA3004 prints the SC-45L English capacity table (plunger size, maximum pressure, and GPM at 200–600 RPM). IOM AP-03-102 PDF p. 11 prints the same model envelope: 60 hp at 600 RPM, 5,280 lb rod load, 2.25 in stroke, 1,683 psi maximum continuous working pressure, 2,500 psi hydrostatic test, and plunger range 2″–2-1/4″. This lists only the lowest printed speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.
The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. Weights: datasheet SC-45L 463 lb vs IOM ductile-iron liquid end about 440 lb; both retained. The SC-45 and SC-45H tables are not inherited. The aplex-sc-45l card remains a table-lead clue only.
Enter discharge gauge pressure and required flow to review the SC-45L printed points.
Open MA3004 datasheet (PDF p. 1 SC-45L table) ↗
Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.
- OEM link snapshot verified 200 No dedicated in-site manual In-site image
- Open catalogue card (existing image)(SC-45L)
- No dedicated parts-book title in the in-site library(No dedicated SC-45L parts-book title in manualLibrary; do not inherit sc-45.pdf / SC-45H.)
- Catalogue image is an existing site overlay — not an OEM workshop-photo or configuration proof; a search hit is not fitment.
- OEM PDFs link to the manufacturer site; not mirrored into the repo. manualLibrary.runtimeImportAllowed=false.
Capacity rows come from the MA3004 SC-45L table; envelope fields checked against the IOM. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit SC-45 / SC-45H.
Myers Aplex SC-65 source-table scenario
Pentair Myers datasheet MA3007 (07-15-21) prints the SC-65 English capacity table (plunger size, maximum pressure, and GPM at 200–550 RPM). IOM AP-03-102 PDF p. 15 prints the same model envelope: 92 hp at 550 RPM, 7,216 lb rod load, 2.75 in stroke, 3,000 psi maximum continuous working pressure, and 4,500 psi hydrostatic test. This lists only the lowest printed speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.
The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. IOM prints plunger sizes 2-3/4″–2-1/4″ while the datasheet SC-65 table also lists smaller sizes—both prints are retained with no silent trim. Datasheet weight header lists L/H only (base SC-65 omitted); IOM lists aluminum-bronze / ductile-iron / forged-steel approximates—retained. The SC-65L and SC-65H tables are not inherited. The aplex-pump-sc-65 card remains a table-lead clue only.
Enter discharge gauge pressure and required flow to review the SC-65 printed points.
Open MA3007 datasheet (PDF p. 1 SC-65 table) ↗
Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.
- OEM link snapshot verified 200 In-site manual In-site image
- Open catalogue card (existing image)(SC-65)
- In-site parts / service manual reader:sc-65
- Catalogue image is an existing site overlay — not an OEM workshop-photo or configuration proof; a search hit is not fitment.
- Shares overlay bytes with a sibling catalogue card; that is not proof of the same unit or configuration.
- OEM PDFs link to the manufacturer site; not mirrored into the repo. manualLibrary.runtimeImportAllowed=false.
Capacity rows come from the MA3007 SC-65 table; envelope fields checked against the IOM. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit SC-65L / SC-65H.
Myers Aplex SC-65L source-table scenario
Pentair Myers datasheet MA3007 prints the SC-65L English capacity table (plunger size, maximum pressure, and GPM at 200–550 RPM). IOM AP-03-102 PDF p. 14 prints the same model envelope: 92 hp at 550 RPM, 7,216 lb rod load, 2.75 in stroke, 1,815 psi maximum continuous working pressure, 2,725 psi hydrostatic test, and plunger range 2-3/4″–2-1/4″. This lists only the lowest printed speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.
The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. IOM prints plunger sizes 2-3/4″–2-1/4″ while the datasheet SC-65L table also lists 3.000″ (Piston)—both prints are retained with no silent trim. Weights: datasheet SC-65L 750 lb vs IOM aluminum-bronze / ductile-iron / forged-steel about 750 / 730 / 775 lb; retained. The SC-65 and SC-65H tables are not inherited. The aplex-sc-65l card remains a table-lead clue only.
Enter discharge gauge pressure and required flow to review the SC-65L printed points.
Open MA3007 datasheet (PDF p. 1 SC-65L table) ↗
Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.
- OEM link snapshot verified 200 No dedicated in-site manual In-site image
- Open catalogue card (existing image)(SC-65L)
- No dedicated parts-book title in the in-site library(No dedicated SC-65L parts-book title in manualLibrary; do not inherit sc-65.pdf / SC-65H.)
- Catalogue image is an existing site overlay — not an OEM workshop-photo or configuration proof; a search hit is not fitment.
- Shares overlay bytes with a sibling catalogue card; that is not proof of the same unit or configuration.
- OEM PDFs link to the manufacturer site; not mirrored into the repo. manualLibrary.runtimeImportAllowed=false.
Capacity rows come from the MA3007 SC-65L table; envelope fields checked against the IOM. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit SC-65 / SC-65H.
Myers Aplex SC-115L source-table scenario
Pentair Myers datasheet MA3011 prints the SC-115L English capacity table (plunger size, maximum pressure, and listed GPM). Engineering data: 1,815 psi maximum continuous working pressure and 2,700 psi hydrostatic test. No dedicated IOM section. This lists only the lowest capacity-consistent speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.
The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. Title says QUINTUPLEX while the header prints NO. OF PLUNGERS 3—both retained, not silent-corrected. Column headers print 350–550 RPM, but GPM ÷ gal/rev equals 200/250/350/450/550—comparison uses capacity-consistent speeds and holds the header conflict. SC-115 / SC-115H tables are not inherited; no base/H catalogue slugs to invent. The aplex-sc-115l card remains a table-lead clue only.
Enter discharge gauge pressure and required flow to review the SC-115L printed points.
Open MA3011 datasheet (PDF p. 1 SC-115L table) ↗
Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.
Capacity rows come from the MA3011 SC-115L table. Results list printed flow points; speeds follow capacity-consistent columns while the header conflict remains held. They do not prove field delivery, bind an installed configuration, or inherit SC-115 / H.
Myers Aplex SC-300L source-table scenario
Pentair Myers datasheet MA3015 (10-15-21) prints the SC-300L English capacity table (plunger size, maximum pressure, and GPM at 200–400 RPM). Engineering data: 1,626 psi maximum continuous working pressure and 2,500 psi hydrostatic test; L maximum speed 400 RPM, rod load 16,780 lb, weight 4,800 lb (separate from SC-300(H)). No dedicated IOM section. This lists only the lowest printed speed on each plunger row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.
The datasheet banner is INTERMITTENT DUTY ONLY; displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. SC-300 / SC-300H tables are not inherited; no base/H catalogue slugs to invent. The aplex-sc-300l card remains a table-lead clue only.
Enter discharge gauge pressure and required flow to review the SC-300L printed points.
Open MA3015 datasheet (PDF p. 1 SC-300L table) ↗
Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.
Capacity rows come from the MA3015 SC-300L table. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit SC-300 / SC-300H.
Kerr KZ-3150PT source-table scenario
The Kerr Pumps OEM PDF (kerrpumps.com/public/pdf/KZ-3150PT.pdf) prints the KZ-3150PT capacity table: diameter, maximum pressure, and GPM at 100–575 RPM. Envelope: 16.7 BHP, 1.5 in stroke, continuous 525 RPM, API-674 recommended maximum 475 RPM, minimum 200 RPM, frame load 1,842 lb. This lists only the lowest printed speed on each diameter row whose GPM and maximum pressure both meet the inputs. No interpolation or catalogue-unit match is made.
Page-1 Specifications Configuration prints Horizontal Triplex Piston while the capacity page title prints Triplex Plunger Pump—both retained, not silent-corrected. Duty is Continuous Duty; the table also prints 100 RPM below the minimum and 575 RPM above continuous, labeled when hit. Displacement assumes 100% volumetric efficiency and power 90% mechanical efficiency. Sibling KZ-3150 (non-PT) has no catalogue slug and is not inherited. The kerr-kz-3150pt card remains a table-lead clue only.
Enter discharge gauge pressure and required flow to review the KZ-3150PT printed points.
Open Kerr KZ-3150PT OEM PDF (capacity page) ↗
Catalogue cards and in-site manuals are in the resource bar below; IOM / service manuals are under Original Sources → Extra OEM pages. This block keeps only the OEM capacity / primary-table deep link.
Capacity rows come from the Kerr OEM KZ-3150PT.pdf. Results list printed points only and do not prove field delivery, bind an installed configuration, or inherit slug-less KZ-3150.