Original table / preliminary screen
Flow and pressure check
Compare required flow and your discharge gauge-pressure value with paired liner and speed ratings in the Weatherford MP-16 manual. This preview does not confirm an installed unit's configuration.
1 original manual · 5 liner sizes · 35 published points
Required duty point
Table check
Enter flow and pressure to see the table check.
Inspect all 35 published points
Cells show rated GPM; column headers show speed and table-header rated HP. Values are transcribed from physical PDF page 5 without interpolation.
| Liner (in) | Liner rated pressure (psi) | 90 RPM 1189 HP | 95 RPM 1255 HP | 100 RPM 1322 HP | 105 RPM 1388 HP | 110 RPM 1454 HP | 115 RPM 1520 HP | 120 RPM 1600 HP |
|---|---|---|---|---|---|---|---|---|
| 7.00 | 3400 | 540 | 570 | 600 | 630 | 660 | 690 | 720 |
| 6.50 | 3900 | 465 | 491 | 517 | 543 | 569 | 595 | 621 |
| 6.00 | 4600 | 397 | 419 | 441 | 463 | 485 | 507 | 529 |
| 5.50 | 5000 | 333 | 352 | 370 | 389 | 407 | 426 | 444 |
| 5.00 | 5000 | 275 | 291 | 306 | 321 | 337 | 352 | 367 |
02 / REVIEW
Engineering checks still required
A table point only shows a published rating. It does not confirm installed configuration, volumetric efficiency, drive capacity, fitment or supply.
- Installed pump nameplate, serial number, fluid end, liner and unit-specific specification sheet
- Available drive power, gear ratio and continuous or intermittent duty
- Suction conditions, mud rheology, solids/gas, temperature and volumetric efficiency
- Discharge piping, pulsation control and pressure definition; final selection requires engineering review
Catalogue records have not been verified against the specific configurations in this manual; this tool neither excludes nor recommends any catalogue record.