Original table / preliminary screen

Flow and pressure check

Compare required flow and your discharge gauge-pressure value with paired liner and speed ratings in the Weatherford MP-16 manual. This preview does not confirm an installed unit's configuration.

1 original manual · 5 liner sizes · 35 published points

Required duty point

Enter US gal/min (GPM) or m³/h.

The input is treated as discharge gauge pressure. The source table says “Rated Pressure” without stating its datum; verify it. Differential pressure and shaft power are not calculated.

Table check

Enter flow and pressure to see the table check.

Inspect all 35 published points

Cells show rated GPM; column headers show speed and table-header rated HP. Values are transcribed from physical PDF page 5 without interpolation.

Liner (in)Liner rated pressure (psi) 90 RPM
1189 HP
95 RPM
1255 HP
100 RPM
1322 HP
105 RPM
1388 HP
110 RPM
1454 HP
115 RPM
1520 HP
120 RPM
1600 HP
7.003400 540570600630660690720
6.503900 465491517543569595621
6.004600 397419441463485507529
5.505000 333352370389407426444
5.005000 275291306321337352367

02 / REVIEW

Engineering checks still required

A table point only shows a published rating. It does not confirm installed configuration, volumetric efficiency, drive capacity, fitment or supply.

  • Installed pump nameplate, serial number, fluid end, liner and unit-specific specification sheet
  • Available drive power, gear ratio and continuous or intermittent duty
  • Suction conditions, mud rheology, solids/gas, temperature and volumetric efficiency
  • Discharge piping, pulsation control and pressure definition; final selection requires engineering review

Catalogue records have not been verified against the specific configurations in this manual; this tool neither excludes nor recommends any catalogue record.